Welcome to the underfloor heating estimate page.

Underfloor Heating Professional Quotation


You can give us all the details that we need to calculate your underfloor heating estimate. After the calculation you will be able to see the total price as well as placing on order immediately.

Underfloor Heating

¹Is underfloor heating your:


The distance between the pipes determines the heat output, the quantity of pipe required and the quantity of ports on the manifold.

main heating? with no radiator (100mm apart = 97 Watt/m² @ 35 C°, 10m of pipe per m², 1 manifold port per 12m² )
basic heating? with no radiator (150mm apart = 84 Watt/m² @ 35 C°, 7.5m of pipe per m², 1 manifold port per 18m² )
additional heating? with radiator (200mm apart = 73 Watt/m² @ 35 C°, 5m of pipe per m², 1 manifold port per 24m² )

(100mm is recomended if UFH will be the only heat source)

²How would you like to control the system?

Don't need controls (No thermostat)
Wired controlling (Wired controls and thermostats)
Wireless controlling (Wireless controls and thermostats)


³Please give us your room details

No. Square Metre: The pipe goes on to: Thermostat in this area:
1.
Staples
ClipRail & Clips
NO PIPE FIXING!
2.
Staples
ClipRail & Clips
NO PIPE FIXING!
3.
Staples
ClipRail & Clips
NO PIPE FIXING!
4.
Staples
ClipRail & Clips
NO PIPE FIXING!
5.
Staples
ClipRail & Clips
NO PIPE FIXING!
6.
Staples
ClipRail & Clips
NO PIPE FIXING!
7.
Staples
ClipRail & Clips
NO PIPE FIXING!
8.
Staples
ClipRail & Clips
NO PIPE FIXING!

Free delivery
*Free Underfloor Heating Delivery within the UK!

If there are any problems or you are just not sure what to do next please contact us on 02920 455 231 or support@hpwarehouse.co.uk

QUOTE HELP GUIDE


1. "Is underfloor heating your:"


- main heating? there is no radiator used with underfloor heating (materials calculated for 100mm pipe centre to centre distance)

- basic heating? there is no radiator used with underfloor heating (materials calculated for 150mm pipe centre to centre distance)

- additional heating? radiator used with underfloor heating in the same room (materials calculated for 200mm pipe centre to centre distance)

2. "How would you like to control the system?"


- Don't need controls: There is no thermostat and relay module

- Wired controlling: Wired thermostat controls the relay module, which is connected to the manifold.

- Wireless controlling: There is no wire (radio frequency) between the thermostat and the relay module. The module is connected to the manifold.

3. "Please give us your room details"


- Square Metre: Type in the size of the individual rooms. Please give us the measurement in m² = square metre (the width of the room multiplied by the length of the room)

- The pipe goes on to: This is where you can select the type of the flooring you have.
*[I don't want fixings] - Fixing is not required to stabilise the pipe to the floor.
*[insulation boards] - The pipe is directly fixed on to the insulation board using staples. 4 staples per metre is recommended.
*[concrete floor] - Laying mats (PipeSulation boards) on to the concrete and then the pipe can easily be clipped into it. Supplied either with 11mm insulation or without insulation. Insulation must be provided, when mats without insulation are being used.
*[wooden beams] - Clips are needed to fix the rails on to the insulation between the beams.

- Thermostat in this area: Select in which room the thermostat is required.